? Actuator ring network bus master station ???????????? --The world's first universal bus master station ICC-SDMS-xR ? ? The
fully redundant valve ring network communication master station
provides reliable redundant connection between the valve actuator and
the host computer (including PLC/DCS, etc.) to ensure real-time reliable monitoring and control between the field electric actuator and the central control system. The bus communicates with more than 120 valve electric actuators in the field through a patented ring network control system based on standard Modbus (RTU\ASCII) protocol . The communication speed can reach up to 115200Bps . Built-in anti-surge The circuit realizes the anti-lightning function of the field bus 20KA . Dual Ethernet independent network segment interface and dual RS232/RS485 serial interface, realize redundant communication with upper computer (including PLC /DCS, etc.); floating IP and port switching technology, realize reliable connection of upper computer when redundant host switching. Modbus TCP as high as 16 ?Servers and 128 ?Clients connection capability , TCP cascade stacking extensions, make-site solutions applied to achieve arbitrary point. Up to 20,000 words of real-time database and detailed real-time status data information, offline / online
configuration and monitoring tool software, non-vendor-limited electric
actuator ring connection, is the only universal high-performance valve
ring in the world network communication controller capable of Rotork , of Limitorque ,
Antoine, Bernard, Tyco, Changzhou Schneider, Yangzhou Hengchun, such as
hundreds of global ?bus electric valve actuators reliable connection
and management . Main technical characteristics 1. Implementation of multi-loop communication structure ?
Innovative loop state detection and healing technology, free loop
configuration technology. The product can implement up to 4 standard
Modbus protocol loop . Real-time monitoring of the health of the loop
enables detection and alarm of actuator faults, loop faults (wire
breaks, grounding, short circuits), and ensures fault-tolerant
communication of loop breakpoints . Adopt
original Ethernet redundancy technology. Keep the IP address of the
primary and backup CPUs unchanged and the primary and secondary
connection channels to achieve continuity of data communication between
the host computers. When acting as a SERVER , the host computer can
connect through a unique IP address regardless of how the active and
standby CPU modules work . In the case of CLENT , each connection can be
configured with an active and standby IP and port to ensure reliable
data communication using the alternate connection in the event of a
primary connection interruption. 2. modular hot plug structure; full redundancy and high reliability hardware design It
adopts functional modular hardware architecture technology, CPU module,
power module, network module, RS232/RS485 module and display module,
etc., through the standard backplane integrated hardware function. These
function modules are redundantly configured according to 1:1 , and the
hot-swap technology ensures that failure of any one of the functional
modules does not affect the normal operation of the whole machine. In
terms of reliability design, the PCB adopts military standard design and
selects wide temperature industrial grade IC to ensure high
availability and applicable environment capability of the hardware. 3. data communication high real-time The
original data preprocessing technology and data communication gap
processing technology are adopted, and a specially optimized real-time
operating system is adopted. The successful application of these
technologies ensures high real-time data communication. 4. the number of valves controlled by the main station is large, the overall cost is low Thanks
to the original multi-ring network communication technology, under the
premise of ensuring fast communication of each ring network, more valves
can be connected to a main station for monitoring and management. This
saves more cost in the case of a large number of valves in one area. 5. the main station inside the whole machine to achieve lightning protection surge protection On
the outside of the RS485 interface of the ring network , a reliable
three-level isolation lightning protection surge protector is provided,
which can reliably protect the direct lightning strike or the induced
lightning in the range of 20 kKA . It can be protected by cable
connections in an open-air environment to protect the equipment from
lightning strikes. 6.
in addition to communication valves, but also access to power systems,
flow meters, communication pressure thermometers and gas alarms and
other instruments and systems According
to the original function design, only the ring network control of the
valve is realized. During the development process, a large number of
expansions are made to the function requirements. For each serial port,
it can be configured into a ring network working mode or an independent
working mode; The connected devices are not limited to valves. The free
access command configuration can be any device with Modbus protocol. It
enables the performance of general-purpose devices to be based on
specialized devices. 7. to achieve remote visualization online configuration and diagnosis An
integrated application tool is configured for the device. The tool
provides configuration, download, debug, monitoring, and diagnostic
functions for device applications. These functions can be performed
through the device's configuration port or remote IP network to achieve
centralized management control and maintenance within the region. 8. intelligent valve equipment management technology The
unique intelligent equipment management technology is used to manage
the valves and other devices on the ring network bus, which can ensure
that the devices on the ring network bus can be intelligently detected
and marked, whether they are out of operation or put into operation. The
communication connection is stopped for the device that is withdrawn
from operation, and the communication efficiency of the device running
online is not affected by the withdrawal of the running device. When the
device that is withdrawn from operation is put into operation again,
the controller can intelligently recognize it and re-incorporate it into
the communication scan. The technology uniquely solves the current
universal Modbus protocol communication device can not solve the impact
of lost devices on the communication efficiency of online devices. The
operating command response is less than 10 milliseconds and the valve
actuator data refresh rate is less than 500 milliseconds. 9. ring network control command enabling technology The
dedicated ring network control command enabling technology can ensure
that the electric actuator in the ring network does not malfunction when
the host computer or the upper control system is abnormal or
unauthorized. 10. Self-diagnosis and status detection with each communication node and hardware module 11. with a complete module self-diagnosis and failure recovery mechanism 12.
up to 20000 th 16 internal bit register configurable real-time database
( 0 to 19999 ), dual-mode bit or word search function 13. DC12V ~ DC30V non-polar wide voltage input, effectively prevent wrong wiring and voltage fluctuations. 14. -25 degrees to +80 degrees ambient operating temperature, no fan design. ? typical application l petrochemical / oil and gas pipelines / depot / LNG????? l water / wastewater treatment????? l conservancy / hydropower / irrigation????? l Food / Pharma????? l large packaging????? l Power generation / transmission and distribution????? ? Ordering Information:
Power | ||
ICC-SDMS-4R | 4-Loops ? Master Control Station | DC ? 12V~30V |
ICC-SDMS-2R | 2-Loops ? Master Control Station | DC ? 12V~30V |
ICC-SDMS-1R | 1-Loop ? Master Control Station | DC ? 12V~30V |
?
?
?
通信地址:中国·上海市普陀区真南路1226弄康建广场8号楼402A,200331
Copyright ? 2008-2019, 大润发糖果派对游戏平台
Address:? 8-402A, Kangjian Plaza, No.1226 Zhennan Road,Putuo District, Shanghai China
??????????????????? Copyright ? 2008-2019, Shanghai Lanyu Electronics Technology Co.ltd
电话 / Tel:+86-21-64040730??? 传真 / Fax: +86-21-64040709??? Web:Http://www.cowboys-shops.com